Author/Authors :
Xianglei Zhu، نويسنده , , Yi Wang، نويسنده , , Jingbo Wang، نويسنده , , Yuanjing Li، نويسنده , , Jianping Cheng، نويسنده ,
Abstract :
The usage of electrodes made of semi-conductive glass is an inspiring way of improving the counting rate capability of resistive plate chamber. We developed 6 and 10-gap multi-gap resistive plate chambers (MRPCs) with low resistive silicate glass electrodes (bulk resistivity ∼1010 Ωcm) for applications in time-of-flight (TOF) at high counting rates. These two prototypes were tested with secondary irradiation from 2.5 GeV proton beam at GSI. Time resolutions below 90 ps and efficiencies above 90% were obtained at counting rates up to 28 kHz/cm2 for the 10-gap MRPC.