Title of article :
Response of light equipment on torsional building with passive tuned mass damper
Author/Authors :
Abhijit K. Agrawal، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
12
From page :
591
To page :
602
Abstract :
Response behavior of an equipment system attached to a linear and torsionally coupled primary system is studied under random ground excitation idealized as broad band stationary random process, represented by white noise. A passive tuned mass damper (TMD) is attached to the equipment system to attenuate its peak responses. The response quantities of interest are relative displacement between the equipment system and the primary system, and absolute acceleration of the equipment system itself. The responses of the equipment system are evaluated under a number of important parametric variations. The variance of response quantities of interest of the equipment system are obtained by frequency domain spectral analysis. The results of the study indicate that attachment of the TMD with the equipment system and torsional coupling of the primary system significantly affect the response behavior of the equipment system.
Keywords :
Primary and secondary systems , Vibration control , Non-classical damping , Torsional coupling , Tuned mass dumper
Journal title :
Computers and Structures
Serial Year :
2000
Journal title :
Computers and Structures
Record number :
1208574
Link To Document :
بازگشت