Title of article :
Parametric investigation of solar chimney with new cooling tower integrated in a single room for New Assiut city, Egypt climate
Author/Authors :
Abdallah، Amr Sayed Hassan نويسنده Department of Architecture , , Hiroshi، Yoshino نويسنده Graduate School of Engineering , , Goto، Tomonobu نويسنده Graduate School of Engineering , , Enteria، Napoleon نويسنده Graduate School of Engineering , , Radwan، Magdy M. نويسنده Department of Architecture , , Eid، M. Abdelsamei نويسنده Department of Architecture ,
Abstract :
Houses in Egypt are often designed without
taking the climate into account sufficiently. Consequently,
new houses often have a poor indoor climate, which affects
comfort, health and building efficiency. In hot and arid
climates, passive cooling system employs non-mechanical
procedures to maintain suitable indoor temperature. Thus,
they have been increasing the influence of the traditional
cooling concepts but with new technology. Therefore,
these conditions encourage such a concept to enhance
natural ventilation with evaporative cooling and save
energy in the New Assiut city. In the present study, the
effect of solar chimney parameters on wind tower parameters
was numerically investigated as a second phase of the
new integrated model. All the detailed mathematical
equations and system description are presented in phase
one. A numerical simulation is implemented in Transient
systems simulation program-Conjunction of multizone
infiltration specialists program softwares. The parametric
studies of the integrated system in phase two were studied
to achieve high performance with new compact small
design especially for the hottest days in the summer season.
The temperature and airflow rates are predicted iteratively
taking into account the zone pressure and the pressure drop
in the evaporative cooler component. The result shows that
the system achieves nearly at least close to 80 % acceptable
comfort range according to Adaptive Comfort
Standard of American Society of Heating, Refrigerating
and Air-Conditioning Engineers with optimum ventilation
rate 414 m3/h for the hottest day. The findings show that
the system achieves high performance in the hottest day
with small solar chimney dimension and is easy to integrate
in the building envelope than the proposed system before
parametric studies in phase one.
Journal title :