Title of article :
Area-specific airflow rates for evaluating the impacts of VOC emissions in U.S. single-family homes
Author/Authors :
Wenhao Chen، نويسنده , , Andrew K. Persily، نويسنده , , Alfred T. Hodgson، نويسنده , , Francis J. Offermann، نويسنده , , Dustin Poppendieck، نويسنده , , Kazukiyo Kumagai، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
8
From page :
204
To page :
211
Abstract :
Product loading ratio and area-specific airflow rate are among the key parameters required for indoor air quality (IAQ) modeling and exposure health assessment of building product emissions. This paper analyzes product loading ratio variations and generates area-specific airflow rate distributions of major categories of interior building products for single family detached (SFD) homes in the U.S. The product categories addressed include ceiling, flooring, interior wallboard & paint, walls & wall coverings, doors, insulation and window treatments. The analysis employs a set of 83 SFD homes that are defined by Persily et al. (2006) as representing 80% of U.S. housing stock built prior to 1998. We first calculate product loading ratios from floor plans of these homes. We then combine the loading ratios with the air change rates previously modeled using CONTAM by Persily et al. (2010) to develop a national, average area-specific airflow rate distribution for each product category. We further analyze the trends affecting area-specific airflow rate distributions in newer homes. Finally, we discuss the implications of these results on assessing IAQ impacts of building products, especially their application to improve product standards for volatile organic compound (VOC) emission testing and evaluation.
Keywords :
Indoor air quality , residential housing , Building products , Volatile organic compounds (VOC) , Air Change Rate , Product loading ratio
Journal title :
Building and Environment
Serial Year :
2014
Journal title :
Building and Environment
Record number :
1218964
Link To Document :
بازگشت