Title of article :
External heat transfer coefficient of a partially sunken sealine
Author/Authors :
Alessandro Terenzi، نويسنده , , Francesco Terra، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
The design of sealines involves calculation of their thermal balance with external environment. Usually in engineering practice one-dimensional codes are used to carry out thermal-hydraulic sizing, and they require the value of an external heat transfer coefficient representing all actual heat exchange phenomena, including 2D or 3D configurations. In the following a simplified approach is presented, for defining a surface averaged heat transfer coefficient of a partially sunken sealine. This coefficient is composed by a contribution due to conduction for the sunken pipe section and another term dealing with forced convection for the upper portion. The second effect is found to dominate the external exchange.
Journal title :
International Communications in Heat and Mass Transfer
Journal title :
International Communications in Heat and Mass Transfer