Title of article
Complete condensation in a vertical tube passive condenser
Author/Authors
Seungmin Oh، نويسنده , , Shripad T. Revankar and Doug Pollock، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
10
From page
593
To page
602
Abstract
An experimental study is performed for the steam condensation in a vertical tube where steam is completely condensed. A condenser tube is submerged in a water pool where the heat from the condenser tube is removed through boiling heat transfer. The experiment data showed that the operating pressure is uniquely determined by inlet steam flow rate for the complete condensation. The condensation heat transfer rate increases and the condensation heat transfer coefficient decreases with the system pressure. For the condenser submerged in a saturated water pool, strong primary pressure dependency was observed on the condensation heat transfer.
Keywords
Condensation heat transfer coefficient , Passive condenser , Complete condensation