Title of article :
Experimental study of thermo-hydraulic and fouling performance of enhanced heat exchangers
Author/Authors :
H. Pahlavanzadeh، نويسنده , , M.R. Jafari Nasr، نويسنده , , S.H. Mozaffari، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
10
From page :
907
To page :
916
Abstract :
The present study investigated the effect of two tube inserts (wire coil and wire mesh) on the heat transfer enhancement, pressure drop and mineral salts fouling mitigation in tube of a heat exchanger. A 3/4-in. tube that is heated by band heaters, is used which simulated a tube of heat exchanger. Working fluid is water with certain quality. The heat transfer rate averagely increased by 22–28% for wire coil (p/d = 0.125, e/d = 0.00375) and 163–174% for wire mesh (medium density) over a plain tube value, depending on type of tube insert, density of wire torsion and flow velocity. However, the pressure drop also increased substantially by 46% for wire coil and 500% for wire mesh. Wire coil insert with vibration mitigate mineral salts fouling (scaling) about 34%, and wire mesh have no effect on scaling, however it sometimes increased deposit rate.
Keywords :
Tube insert , Fouling mitigation , Heat transfer enhancement , Pressure drop , Friction factor , Wire coil , Wire mesh