Title of article :
Effect of porous coating on two-phase pressure drop of water during up-flow boiling in tubes
Author/Authors :
Sebiha Yildiz، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
12
From page :
326
To page :
337
Abstract :
This paper focuses on the effects of porous coating on two-phase flow pressure drop during up-flow boiling of water in vertical tubes. The experiments were carried out under subcooled fluid–inlet conditions (5–73 K) for different mass fluxes (200–400 kg/m2 s) and pressures (0.11–0.69 MPa). The measured pressure drops were compared first with each other, and then with correlations from literature. It was found that the best agreement between predicted and measured values is obtained by the method of Thom [3] for a smooth tube and by Müller-Steinhagen and Heckʹs method [4] for a porous coated tube respectively.
Keywords :
Pressure drop , Two-phase up-flow , Smooth tube , Porous coated tube , water
Journal title :
International Communications in Heat and Mass Transfer
Serial Year :
2008
Journal title :
International Communications in Heat and Mass Transfer
Record number :
1220273
Link To Document :
بازگشت