Title of article :
Cryogenic thermal analysis of the HANARO cold neutron moderator cell
Author/Authors :
Gee Y. Han، نويسنده , , Kye H. Lee، نويسنده , , Heonil Kim، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
6
From page :
583
To page :
588
Abstract :
Accurate prediction of a temperature distribution is very important for investigating the heat transfer characteristics in a cryogenic system such as a cold neutron moderator cell. The cold neutron moderator cell is a 13.2-cm-diameter cylinder with the liquid hydrogen in it contained by an aluminum alloy cell. It will be placed in a cold neutron hole that is inside the heavy water reflector tank of HANARO. The liquid hydrogen serves both as a neutron moderator and a single-phase cryogenic coolant for the cold neutron moderator cell. For the cold neutron moderator cell, its interactions with neutrons and gamma-rays produce a heat load of 629 W on the aluminum alloy cell and liquid hydrogen itself. A half of the cold neutron moderator cell was modeled with a three-dimensional axisymmetric cylinder geometry by using the HEATING 7.3 code. A numerical analysis was performed to determine the temperature distribution over the entire inner surface of the moderator cell, whose moderator and cell walls are heated differently, under a steady-state operating condition. This paper presents the steady-state temperature distribution for providing the cryogenic thermal analysis and for supporting the thermal stress analysis of the moderator cell walls.
Keywords :
Liquid hydrogen , Nuclear heating , HANARO , CNS , Thermo-siphon loop
Journal title :
International Communications in Heat and Mass Transfer
Serial Year :
2008
Journal title :
International Communications in Heat and Mass Transfer
Record number :
1220301
Link To Document :
بازگشت