• Title of article

    Two-phase closed thermosyphon vapor-chamber system for electronic cooling

  • Author/Authors

    Te-En Tsai، نويسنده , , Hsin-Hsuan Wu، نويسنده , , Chih-Chung Chang، نويسنده , , Sih-Li Chen، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    6
  • From page
    484
  • To page
    489
  • Abstract
    This article experimentally investigates a two-phase closed thermosyphon vapor-chamber system for electronic cooling. A thermal resistance net work is developed in order to study the effects of heating power, fill ratio of working fluid, and evaporator surface structure on the thermal performance of the system. The results indicate that either a growing heating power or a decreasing fill ratio decreases the total thermal resistance, and the surface structure also influences the evaporator function prominently. A reasonable agreement with Rohesnowʹs empirical correlation is found for the evaporator. An optimum overall performance exists at 140 W heating power and 20% fill ratio with sintered surface, and the corresponding total thermal resistance is 0.495 °C W−1.
  • Keywords
    thermosyphon , Vapor chamber , Thermal Resistance , electronic cooling , Boiling enhancement
  • Journal title
    International Communications in Heat and Mass Transfer
  • Serial Year
    2010
  • Journal title
    International Communications in Heat and Mass Transfer
  • Record number

    1220673