Title of article
Experimental investigation of cooling of heated circular disc using inclined circular jet
Author/Authors
Hakan F. Oztop، نويسنده , , Yasin Varol، نويسنده , , Ahmet Koca، نويسنده , , Mujdat Firat، نويسنده , , Betül Turan، نويسنده , , Ilhan Metin، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2011
Pages
12
From page
990
To page
1001
Abstract
An experimental study is performed to examine the heat transfer characteristics of impinging circular jet onto a heated circular disc. The disc is heated under constant heat flux and it has an inclination angle with impinging jet in the range of 90° ≤ φ ≤ 150°. The air is supplied using a radial fan. The fluid flows through a designed tunnel. Experiments were performed under different Reynolds number, 2800, 9000, and 36,000, and different values of inclination angle of the disk and jet-to-plate distance to jet diameter ratio H/Dh as 5, 10, and 15. The results of experiments showed that the most effective parameter is the inclination angle between jet and heater. Both locations of stagnation point and heat transfer are affected from this parameter.
Keywords
Jet impingement , Circular disc , Circular jet , heat transfer
Journal title
International Communications in Heat and Mass Transfer
Serial Year
2011
Journal title
International Communications in Heat and Mass Transfer
Record number
1220972
Link To Document