Abstract :
In order to control the heat saturation time, the temperature field of the regenerators of high temperature air combustion (HTAC) technology after reheating furnace was studied. A one-dimensional unsteady mathematical model was established and discretized through finite difference method. The relationship between the heat saturation time and some factors was determined through the calculation of a program developed by language C. The heat saturation time decreases with the increase of heat convection coefficient, however, the increase of heat capacity, density and radius of regenerator all increase the heat saturation time approximately linearly.
Keywords :
solid spherical regenerator , heat saturation time , Mathematical model