Title of article :
Giant Stress-Impedance Effect in Co71.8Fe4.9Nb0.8Si7.5B15 Glass-Covered Amorphous Wires Original Research Article
Author/Authors :
Zheng CHEN، نويسنده , , Deren Li، نويسنده , , Zhichao Lu، نويسنده , , Shaoxiong Zhou، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
2
From page :
49
To page :
50
Abstract :
The giant stress-impedance (GSI) effect in as-cast and DC current annealed Co71.8Fe4.9Nb0.8Si7.5B15 amorphous glass-covered wires is presented. The SI ratio of the as-cast sample exhibits negative GSI effect. For the sample annealed by 60 mA DC current, the SI ratio first increases with applied tensile stress, then decreases. The maximum ΔZ/Z ratio of 304% is obtained. Frequency dependence in the range from 1 to 110 MHz of the GSI effect is investigated. Experimental results show that the real part R and the imaginary part X of impedance play an important role at high frequency and low frequency, respectively. At 1 MHz, the maximum ΔX/X ratio of 1 448% is obtained. At 110 MHz, the maximum ΔR/R ratio of 648% is obtained.
Keywords :
giant stress-impedance , DC annealing , amorphous wire
Journal title :
Journal of Iron and Steel Research
Serial Year :
2006
Journal title :
Journal of Iron and Steel Research
Record number :
1234749
Link To Document :
بازگشت