Title of article :
Measurement of charge transfer in electrostatic discharges
Author/Authors :
J.N. Chubb، نويسنده , , E-mail the corresponding author، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
5
From page :
321
To page :
325
Abstract :
Experimental studies are reported that show the errors that arise in using unshielded probes for measuring charge transfer in electrostatic discharges. Comparable errors will apply where unshielded probes are used for current flow measurements. Errors are avoided by using shielded probes with an appropriate charge measurement circuit. These results are relevant to the design of probes to be included in IEC Standards.
Keywords :
Electrostaticdischargemeasurements , Dischargeprobes
Journal title :
JOURNAL OF ELECTROSTATICS
Serial Year :
2006
Journal title :
JOURNAL OF ELECTROSTATICS
Record number :
1264777
Link To Document :
بازگشت