• Title of article

    Mechanism of electrohydrodynamically induced flow in a wire-non-parallel plate electrode type gas pump

  • Author/Authors

    J.S. Chang، نويسنده , , H. Tsubone، نويسنده , , Y.N. Chun، نويسنده , , A.A. Berezin، نويسنده , , K. Urashima، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    5
  • From page
    335
  • To page
    339
  • Abstract
    An experimental investigation and one-dimensional modeling have been conducted to study the mechanism of net flow direction induced by electrohydrodynamic (EHD) forces in a wire-non-parallel plate electrode type EHD gas pump. The experiments were conducted with various different locations of corona wire electrode for negative and positive applied voltage from 0 to 14 kV at atmospheric pressure and room temperature, where air was used as the working fluid. A one-dimensional cross-sectional averaged model based on mass and momentum conservation as well as Poisson electric field and ion transport equations was also developed. The results show that the net flow direction of electrohydrodynamically induced gas flow in a wire-non-parallel plate electrode system significantly depends on the location of the corona wire electrode relative to the grounded electrode position. The effect of conversion angle of non-parallel plate electrode on the net flow direction and pressure drop also was investigated and discussed in detail.
  • Keywords
    Coronadischarge , Electrohydrodynamics , Gaspump , Thermalmanagement , Ionicwind
  • Journal title
    JOURNAL OF ELECTROSTATICS
  • Serial Year
    2009
  • Journal title
    JOURNAL OF ELECTROSTATICS
  • Record number