Title of article
Current analysis of DC negative corona discharge in a wire-cylinder configuration at high ambient temperatures
Author/Authors
Gang Xiao، نويسنده , , Xihui Wang، نويسنده , , Jiapeng Zhang، نويسنده , , Mingjiang Ni، نويسنده , , Xiang Gao، نويسنده , , Kefa Cen، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
13
From page
107
To page
119
Abstract
To study the characteristics of DC negative corona discharge in a wire-cylinder configuration at an ambient temperature range of 350–850 °C, the I–V characteristics and the current composition are analyzed under different conditions. A simple method is proposed to determine the DC corona onset threshold voltage. At high ambient temperatures, in the DC negative corona discharge gap, some electrons are not attached to the electronegative gas molecules and move to the anode tube. Thus, these electrons form an electron current, which may account for most of the total discharging current. The ratio of the electron current to the total discharging current increases with increasing temperature. In a mixture of O2 and N2 and a mixture of CO2 and N2, the ratio of electron current increases with increasing N2 content in the mixtures. The cathode material has little influence on the corona discharge characteristics at high ambient temperatures.
Keywords
Coronadischarge , Coronaonsetthresholdvoltage , Particlechargingmechanism , Hotgasclean-up , Electrostaticprecipitation