Title of article
Development of ceramic electrochemical sensor based on Bi2Ru2O7+x − RuO2 sub-micron oxide sensing electrode for water quality monitoring
Author/Authors
Serge Zhuiykov، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
7
From page
2407
To page
2413
Abstract
Sub-micron Bi2Ru2O7+x + RuO2 oxide sensing electrodes (SE) for water quality sensors were prepared on platinised ceramic substrate of the sensor. Their morphology was analysed by X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy-dispersive X-ray analysis (EDX). Sensing properties of the Bi2Ru2O7+x + RuO2-SE were investigated for potentiometric detection of pH and dissolved oxygen (DO) in water in the temperature range of 4–30 °C. Sensor was capable to measure DO from 0.5 to 8.0 ppm and pH from 2.0 to 13.0, respectively. The obtained results show acceptable linearity of the measuring characteristics. Long-term stability trial for Bi2Ru2O7+x + RuO2-SE revealed that bio-fouling can be one of the main destructive factors affecting the performance of the sensors in the long run. The screen-printing technology used in the multi-sensory implementation provides fundamental properties of miniaturization, reasonable accuracy and low cost.
Keywords
Solid-state sensors , Oxide sensing electrode , water quality monitoring , RuO2