Davari، A.R نويسنده , , Booshehri ، M نويسنده Dept. of Oral Radiology, School of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran. , , Ezoddini ، F نويسنده Dept. of Oral Radiology, School of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran. , , Danesh Kazemi ، AR نويسنده Dept. of Operative Dentistry, School of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran , , Mousavinasab ، M نويسنده Dept. of Operative Dentistry, School of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran. , , Rashidinejad ، M نويسنده Dentist ,
Issue Information :
فصلنامه با شماره پیاپی 28 سال 1389
Pages :
7
From page :
215
To page :
221
Abstract :
بيان مساله: تشخيص پوسيدگي هاي ميان دنداني با استفاده از پرتونگاري بايت وينگ يك روش باليني مناسب است. بسياري از بررسي ها نشان داده اند، كه پرتونگاري مستقيم ديجيتال و فيلم هاي رايج دندانپزشكي در تشخيص پوسيدگي هاي ميان دنداني توانايي همانندي دارند. هدف: بر اين پايه هدف از اين پژوهش، مقايسه ي اثرات دستكاري نگاره هاي ديجيتال به صورت رنگ كاذب در توانايي تشخيص پوسيدگي هاي آغازين ميان دنداني بود. مواد و روش: نگاره هاي ديجيتال 102 سطح ميان دنداني دندان هاي پرمولر كشيده شده ي انساني با و بي استفاده از برنامه ي نرم افزاري سودوكالر (Pseudocolor) توسط سه مشاهدگر ارزيابي گرديد. دندان ها برش داده شده و به وسيله ي ميكروسكوپ براي تعيين استاندارد طلايي بررسي شدند. سپس، ضريب هماهنگي كاپا و درصد هماهنگي كلي ارزيابي گرديدند. يافته ها: حساسيت و ويژگي در دو گونه نگاره ي رنگي و سياه و سفيد با استفاده از نرم افزار در نگاره هاي ديجيتال 7/66 و 60 درصد و براي پرتونگاري ديجيتال مستقيم رنگي شده 5/80 و 50 درصد به دست آمد، گر چه تفاوت آماري معنادار ميان دو گونه نگاره ديده نشد (12/0= p). نتيجه گيري: در بررسي كنوني، استفاده از برنامه ي نرم افزاري رنگ كاذب نتوانست تفاوت آماري چشمگيري ميان نگاره ي ديجيتال معمولي و رنگي شده ايجاد نمايد. واژگان كليدي: رنگ كاذب، پرتونگاري ديجيتال، پوسيدگي
Abstract :
Statement of Problem: Bitewing radiography is a suitable clinical technique for the diagnosis of interproximal caries. Many researches performed in this field have shown that direct digital radiography and conventional radiography films in dentistry are similar in detecting inter-proximal caries. Purpose: To compare the effects of image processing mode of colorize on the efficacy of the detection of interproximal carious lesions viewed in direct digital radiography. Methods and Material: A total of 102 proximal surfaces of the extracted human premolar teeth on direct digital images with and without application of pseudocolor filter were evaluated by three observers. The teeth were sectioned and viewed microscopically to determine the gold standard. The kappa value agreement ratio was calculated. Results: Sensitivity and specificity values in normal digital images were found to be 66.7% and 60% and for colorized images 80.5% and 50%, respectively. However, there was no statistically significant difference between the two types of images (p = 0.12). Conclusion: In this study, application of pseudocolor software failed to result in statistically significant differences between normal and colorized digital images.
Journal title :
Journal of Dentistry :Shiraz University of Medical Sciences
Serial Year :
1389
Journal title :
Journal of Dentistry :Shiraz University of Medical Sciences
Record number :
1332992
Link To Document :
بازگشت