Title of article :
Application of Cold-Induced Aggregation Microextraction Based on Ionic Liquid for Determination of Trace Amount of Cadmium and Lead in Powder Milk Samples
Author/Authors :
Delavar، Mostafa نويسنده Pharm D, Department of Pharmacology, Arak University of Medical Sciences, Arak, Iran , , Ramezani، Majid نويسنده , , ABDOLLAHI، MAHDI نويسنده , , Navabi، Atefeh نويسنده Food and Beverages and Decorative and Hygienic Products Control Laboratory, Arak University of Medical Sciences, Arak, Iran. , , Baderestani، Abdolreza نويسنده MSc, Expert of Control Office on Food and Beverage, Decorative, Hygienic Products of Arak’s Medical Sciences University. , , Hadavand، Shoukofeh نويسنده MSc, Chemistry Expert Advisor, Arak University of Medical Sciences, Arak, Iran. , , Sadeghi، Masoodeh نويسنده MSc, Chemistry Expert Advisor, Arak University of Medical Sciences, Arak, Iran. ,
Issue Information :
دوماهنامه با شماره پیاپی 25 سال 2014
Pages :
7
From page :
1041
To page :
1047
Abstract :
Background: cold-induced aggregation micro extraction based (CIAME) based on ionic liquid was used as a rapid and simple method for determination trace amounts of cadmium and lead in milk powder by analysis with flame atomic absorption spectrometry (FAAS). Methods: Sample solution containing of Cd2+ and Pb2+ in dynamic range, phosphate buffer (pH = 9, 3 ml), diethyl dithiocarbamate (complexing agent), Triton X-100, NaPF6 ,[HMIM][PF6] (extraction solvent) were transferred into conical bottom glass tube. Sample was kept in a thermostated bath and then ice bath; a cloudy solution was formed. Two phases separated by centrifugation. After removing of aqueous phase, IL-phase was dissolved in methanol and diluted was injected to the FAAS by microsampler introduction. Results: ILs, containing imidazoliumcation and hexafluoro phosphate anion, [HMIM][PF6](70mg), 200 mg NaPF6 ,0.01 mol.L-1 DDTC, 0.015% of Triton X-100 obtained, pH 9 and centrifuge time; 5 min (4000 rmp) was chosen. Detection limit were obtained 0.12 µgL-1, 1.61µgL-1, RSD 0.95%, 2.2% and enrichment factor of 70, 67 for Cd and Pb, respectively. Conclusion: CIAME allows determination of cadmium and lead in real samples in a simple, rapid and safe method with only a small amount of ionic liquid was used. In comparison with the organic solvent extraction, CIAME is much safer and the determination of species in high ionic strength samples is possible.
Journal title :
Iranian Journal of Toxicology
Serial Year :
2014
Journal title :
Iranian Journal of Toxicology
Record number :
1333807
Link To Document :
بازگشت