Title of article :
Direct measurement of the atmospheric neutron flux in the energy range 10–500 MeV
Author/Authors :
Bonardi، نويسنده , , Antonio and Aglietta، نويسنده , , Marco Brayda-Bruno، نويسنده , , Gianmarco and Fulgione، نويسنده , , Walter and Bergamini Machado، نويسنده , , Ana Amelia Peixoto Boischio، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
5
From page :
225
To page :
229
Abstract :
The results of a direct measurement of the atmospheric neutron flux in the energy range 10–500 MeV performed at 42°25′11″ N, 13°31′2″ E, rigidity cutoff 6.3 GV, altitude 970 m a.s.l. (LNGS external site) on November 2008, during minimum solar activity, are reported. tector consists of a 1.5 × 1 × 1 m3 stainless steel tank filled with 1.2 tons of 0.1% Gd doped liquid scintillator, monitored by three photomultipliers and surrounded by a 4π active muon veto. The measurement is performed by observing events formed by two un-vetoed pulses inside a temporal window 95 μs long: the first one due to a recoiling proton scattered by a neutron, the second one due to the neutron capture (n, Gd). sulting atmospheric neutron fluxes are: > 10 MeV ) = 47 ± 5 neutrons s - 1 m - 2 ; Φ ( E > 20 MeV ) = 42 ± 4 neutrons s - 1 m - 2 .
Keywords :
neutrons , flux , Measurement
Journal title :
Astroparticle Physics
Serial Year :
2010
Journal title :
Astroparticle Physics
Record number :
1335992
Link To Document :
بازگشت