• Title of article

    Design and performance of the XENON10 dark matter experiment

  • Author/Authors

    Aprile، نويسنده , , E. and Angle، نويسنده , , J. D. Arneodo، نويسنده , , F. and Baudis، نويسنده , , L. and Bernstein، نويسنده , , A. and Bolozdynya، نويسنده , , A. and Brusov، نويسنده , , P. J. Coelho and J. Argain، نويسنده , , L.C.C. and Dahl، نويسنده , , C.E. and DeViveiros، نويسنده , , L. and Ferella، نويسنده , , A.D. and Fernandes، نويسنده , , L.M.P. and Fiorucci، نويسنده , , S. and Gaitskell، نويسنده , , R.J. and Giboni، نويسنده , , K.L. and Gomez، نويسنده , , R. and Hasty، نويسنده , , R. and Kastens، نويسنده , , L. and Kwong، نويسنده , , J. and Lopes، نويسنده , , J.A.M. and Madden، نويسنده , , N. and Manalaysay، نويسنده , , A. and Manzur، نويسنده , , A. and McKinsey، نويسنده , , D.N. and Monzani، نويسنده , , M.E. and Ni، نويسنده , , K. and Oberlack، نويسنده , , U. and Orboeck، نويسنده , , J. and Orlandi، نويسنده , , D. R. Plante and G. von Oppen ، نويسنده , , G. M. Santorelli، نويسنده , , R. and dos Santos، نويسنده , , J.M.F. and Shagin، نويسنده , , P. and Shutt، نويسنده , , Tracy T. and Sorensen، نويسنده , , P. and Schulte، نويسنده , , S. and Tatananni، نويسنده , , E. and Winant، نويسنده , , C. and Yamashita، نويسنده , , M.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    20
  • From page
    679
  • To page
    698
  • Abstract
    XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso Underground Laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulation data. The results on the detector’s energy threshold, position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (<10 keVr) and low background rate achieved.
  • Keywords
    Time projection chamber , direct detection , Liquid xenon , Dark matter
  • Journal title
    Astroparticle Physics
  • Serial Year
    2011
  • Journal title
    Astroparticle Physics
  • Record number

    1336049