• Title of article

    Energy efficiency analysis of air cycle heat pump dryers

  • Author/Authors

    Braun، نويسنده , , J.E. and Bansal، نويسنده , , P.K. and Groll، نويسنده , , E.A.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    12
  • From page
    954
  • To page
    965
  • Abstract
    In this paper, the feasibility of an air heat pump (reversed Brayton) cycle for tumbler clothes dryers is investigated. The goal is to increase the energy efficiency as compared to conventional electrically heated driers. Relatively simple models were used to compare the energy efficiency of the heat pump drier with that of a conventional air vented drier. The components were modeled using overall performance indices and thermodynamic relations. An air cycle heat pump dryer with practical components was found to be capable of significant efficiency improvements as compared with conventional dryers.
  • Keywords
    Design , Modelling , Pompe à chaleur , Déshydratation , Conception , Air/air , Cycle à air , Modélisation , dehydration , Air/air , Drying , Heat pump , Séchage
  • Journal title
    International Journal of Refrigeration
  • Serial Year
    2002
  • Journal title
    International Journal of Refrigeration
  • Record number

    1339485