Title of article :
X-ray investigation of a domestic refrigerator. Observations at 25°C ambient temperature
Author/Authors :
Inan، نويسنده , , Cemil and Gonul، نويسنده , , Turgay and Tanes، نويسنده , , M.Yalcin، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
In this study, the transient behavior of a domestic refrigerator is investigated by the use of an X-ray system. The studies are made on a two-door upright freezer with a volume of 435 liters, and which has an automatic defrost feature. The refrigerant is R134a. During the experimental study, ambient temperature is held at 25±2 °C. Real time X-ray video images of the refrigeration circuit are taken during the pull-down (cooling down of the refrigerator from ambient temperature) and cyclic periods as well. X-ray images are recorded by focusing to on the dryer, capillary exit, evaporator inlet, and accumulator regions specifically. In order to watch evaporator and dryer sections continuously, two identical experiments are made while the probe is focused on either the evaporator or dryer sections each time. By matching the video images and temperature data, the flow regimes, charge inventory, accumulator functioning, and changes of subcooling degree at dryer inlet are explained. Possible flow induced noise mechanisms are identified.
Keywords :
Circuit , Research , Réfrigératuer domestique , X-Ray , Fonctionnement , Frigorigène , Circuit , Rayon X , domestic refrigerator , Operation , Refrigerant , Recherche
Journal title :
International Journal of Refrigeration
Journal title :
International Journal of Refrigeration