Title of article :
Performance analysis of a feasible air-cycle refrigeration system for road transport
Author/Authors :
Spence، نويسنده , , Stephen W.T. and John Doran، نويسنده , , W. and Artt، نويسنده , , David W. and McCullough، نويسنده , , G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
The performance of an air-cycle refrigeration unit for road transport, which had been previously reported, was analysed in detail and compared with the original design model and an equivalent Thermo King SL200 vapour-cycle refrigeration unit. Poor heat exchanger performance was found to be the major contributor to low coefficient of performance values. Using state-of-the-art, but achievable performance levels for turbomachinery and heat exchangers, the performance of an optimised air-cycle refrigeration unit for the same application was predicted. The power requirement of the optimised air-cycle unit was 7% greater than the equivalent vapour-cycle unit at full-load operation. However, at part-load operation the air-cycle unit was estimated to absorb 35% less power than the vapour-cycle unit. The analysis demonstrated that the air-cycle system could potentially match the overall fuel consumption of the vapour-cycle transport refrigeration unit, while delivering the benefit of a completely refrigerant free system.
Keywords :
Performance , Air-cycle system , Refrigerated transport , Research , COP , Performance , COP , Air , Transport frigorifique , Recherche , Thermodynamic Cycle , Cycle thermodynamique , refroidisseur dיair , Air
Journal title :
International Journal of Refrigeration
Journal title :
International Journal of Refrigeration