Title of article :
Nonlinear cyclic response of laminated glass FRP tubes filled with concrete
Author/Authors :
Yutian Shao ، نويسنده , , Dr. Amir Mirmiran، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
11
From page :
91
To page :
101
Abstract :
Fiber reinforced polymer (FRP) materials are generally known for their linear elastic response to failure. The present study evaluated the implications of using FRP as primary and sole reinforcement for concrete structures in seismic regions through an experimental and analytical investigation on the cyclic response of two different types of laminated glass FRP tubes filled with concrete. The study showed that concrete-filled tubes can be designed with an appropriate laminate structure for a ductility level comparable to that of conventional reinforced concrete columns. The nonlinearity and ductility in these types of structures stem from the off-axis response of the FRP tube. A hysteretic model was developed for the tube, and was cast into a two-dimensional three-node combined fiber element for the concrete-filled FRP tube. Good agreement was shown between the analytical models and the experimental results.
Keywords :
Composite tube , Nonlinearity , Fiber orientation , Ductility , Cyclic loading
Journal title :
COMPOSITE STRUCTURES
Serial Year :
2004
Journal title :
COMPOSITE STRUCTURES
Record number :
1340104
Link To Document :
بازگشت