Title of article
Dynamic behavior of a direct expansion evaporator under frosting condition. Part II. Field investigation on a shipping container
Author/Authors
Tso، نويسنده , , C.P. and Cheng، نويسنده , , Y.C. and Lai، نويسنده , , A.C.K.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
8
From page
624
To page
631
Abstract
A field investigation is performed on the frost formation at an evaporator of a commercial full-scale refrigerated container that uses R-12 as the working refrigerant. Results when compared with those from a numerical model presented earlier show that the model is capable of predicting the dynamic behavior of a direct expansion evaporator under both non-frosting and frosting conditions. The air outlet and energy transferred compare well between experiment and model, and within 20% for the air pressure drop. The frost occurrence and propagation agree well generally, with the frost formation first occurring at the first row where the refrigerant enters the evaporator.
Keywords
Refrigerated container , Marine transport , Experiment , Evaporator , finned tube , Frost formation , Performance , ةvaporateur , Expérimentation , Conteneur frigorifique , Tube alieté , Transport maritime , Performance , Givrage