Title of article
Experimental investigation of the performance of a Ranque–Hilsch vortex tube with regard to a plug located at the hot outlet
Author/Authors
Dincer، نويسنده , , K. and Baskaya، نويسنده , , S. and Uysal، نويسنده , , B.Z. and Ucgul، نويسنده , , I.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
8
From page
87
To page
94
Abstract
In this study, effects of position, diameter (5, 6, 7, 8 mm) and angle (30°–180°) of a mobile plug, located at the hot outlet side in a Ranque–Hilsch Vortex Tube (RHVT), were determined experimentally for best performance. In addition to plug parameters, effects of supply pressure (200–420 kPa) and number of nozzles (2, 4, 6) were also studied. The internal diameter (D) of the vortex tube used in the experiments was 9 mm; the ratio of the length of the vortex tube to its diameter (L/D) was 15. Four different plug locations were studied. The maximum difference in the temperatures of hot and cold streams was obtained for the plug diameter of 5 mm, tip angles of 30° and 60°, 4 nozzles and by keeping the plug location at the far extreme end.
Keywords
Expérimentation , Ranque-Hilsch , Tuyauterie , Performance , Géométrie , Paramètre , vortex tube , Ranque–Hilsch , Performance , Experiment , Parameter , piping , Geometry , Système frigorifique , Tube vortex , Refrigeration system
Journal title
International Journal of Refrigeration
Serial Year
2009
Journal title
International Journal of Refrigeration
Record number
1341877
Link To Document