Title of article :
Effect of twisted tape insert on heat transfer and pressure drop in horizontal evaporators for the flow of R-134a
Author/Authors :
Akhavan-Behabadi، نويسنده , , M.A. and Kumar، نويسنده , , Ravi and Mohammadpour، نويسنده , , A. and Jamali-Asthiani، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
An experimental study has been carried out on the heat transfer enhancement and pressure drop characteristics in presence of twisted tape inserts, during flow boiling of R-134a, inside a horizontal evaporator. The test-evaporator was an electrically heated 1260 mm long copper tube with 7.5 mm inside diameter. The experiments were performed for plain flow and four tubes with twisted tapes of 6, 9, 12 and 15 twist ratios and four refrigerant mass velocities of 54, 85, 114 and 136 kg/s m2 for each tape. It has been found that the twisted tape inserts enhance the heat transfer coefficient on relatively higher pressure drop penalty, in comparison to that for the plain flow.
Keywords :
Transfert de chaleur , Chute de pression , Evaporator , Horizontal tube , insert , Experiment , Boiling , R134a , heat transfer , ةvaporateur , Pressure drop , Tube horizontal , insert , Expérimentation , ةbullition , R134a
Journal title :
International Journal of Refrigeration
Journal title :
International Journal of Refrigeration