Title of article
Numerical evaluation of the retrofit effectiveness for GFRP retrofitted concrete slab subjected to blast pressure
Author/Authors
Jin-Won Nam، نويسنده , , Ho-Jin Kim، نويسنده , , Sung Bae Kim، نويسنده , , Na Hyun Yi، نويسنده , , Jang-Ho Jay Kim، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
11
From page
1212
To page
1222
Abstract
For retrofitting structures against blast loads, sufficient ductility and strength should be provided by using high-performance materials such as fiber reinforced polymer (FRP) composites. The effectiveness of retrofit materials needs to be precisely evaluated for the retrofitting design based on the dynamic material responses under blast loads. In this study, refined FEM analysis with high-strain rate dependent material model and debonding failure model is conducted for evaluating the FRP retrofitting effectiveness. The structural behavior of reinforced concrete (RC) slab retrofitted with glass fiber reinforced polymer (GFRP) under blast pressure is simulated and the analysis results are verified with the previous experimental results.
Keywords
Fiber reinforced polymer (FRP) , Debonding failure model , Retrofitting effectiveness , Blast load , High-strain rate dependent material model , Refined FEM analysis , Reinforced concrete (RC)
Journal title
COMPOSITE STRUCTURES
Serial Year
2010
Journal title
COMPOSITE STRUCTURES
Record number
1343182
Link To Document