Title of article :
Experimental investigation of the effects of threefold type Ranque–Hilsch vortex tube and six cascade type Ranque–Hilsch vortex tube on the performance of counter flow Ranque–Hilsch vortex tubes
Author/Authors :
Dincer، نويسنده , , Kevser، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
6
From page :
1366
To page :
1371
Abstract :
In this study, performances of Ranque–Hilsh Vortex Tubes (RHVTs) were experimentally investigated under three different situations based on inlet pressure and the ratio of mass flow rate of the cold stream to the mass flow rate of the inlet stream (ξ). 1st situation is the conventional RHVT. 2nd situation is the threefold cascade type RHVT. Here three RHVTs were used. 3rd situation deals with the six cascade type RHVT. In this case, six RHVTs were used. When all the test results under Pi = 360 kPa and Pi = 400 kPa pressure conditions are compared, it is found that the best performance occurs at the 3rd situation. Moreover, the performance of the 3rd situation at Pi = 400 kPa pressure is higher than that at Pi = 360 kPa. Maximum values of ΔT and ξ are obtained as 67.6 °C and 0.9 for 3rd situation.
Keywords :
Géométrie , vortex tube , Experiment , Geometry , Tube vortex , Ranque-Hilsch , Expérience , Ranque–Hilsch
Journal title :
International Journal of Refrigeration
Serial Year :
2011
Journal title :
International Journal of Refrigeration
Record number :
1343317
Link To Document :
بازگشت