• Title of article

    An experimental study of passive regenerator geometries

  • Author/Authors

    Engelbrecht، نويسنده , , K. and Nielsen، نويسنده , , K.K. and Pryds، نويسنده , , N.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    6
  • From page
    1817
  • To page
    1822
  • Abstract
    Active magnetic regenerative (AMR) systems are being investigated because they represent a potentially attractive alternative to vapor compression technology. The performance of these systems is dependent on the heat transfer and pressure drop performance of the regenerator geometry. Therefore this article studies the effects of regenerator geometry on performance for flat plate regenerators. This paper investigates methods of improving the performance of flat plate regenerators for use in AMR systems and studies how manufacturing variation affects regenerator performance. In order to eliminate experimental uncertainty associated with magnetocaloric material properties, all regenerators are made of aluminum. The performance of corrugated plates and dimpled plates are compared to traditional flat plate regenerators for a range of cycle times and utilizations. Each regenerator is built using 18 aluminum plates with a 0.4 mm thickness, which allows their performance to be compared directly.
  • Keywords
    Experimentation , Réfrigérateur magnétique , Expérience , Régénérateur , Magnetic refrigerator , Regenerator
  • Journal title
    International Journal of Refrigeration
  • Serial Year
    2011
  • Journal title
    International Journal of Refrigeration
  • Record number

    1343777