Title of article :
Performance analysis of multi-stage thermoelectric coolers
Author/Authors :
Karimi، نويسنده , , G. and Culham، نويسنده , , J.R. and Kazerouni، نويسنده , , V.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
7
From page :
2129
To page :
2135
Abstract :
Multi-stage thermoelectric coolers offer larger temperature differences between heat source and heat sink than single-stage thermoelectric coolers. In this paper, a pyramid-type multi-stage cooler is analyzed, focusing on the importance of maximum attainable target heat flux and overall coefficient of performance, COP. Having considered the COP and the thermal resistance of a heat sink as key parameters in the design of a multi-stage thermoelectric cooler, analytical formulas for COP and heat sink thermal resistance versus working electrical current are derived. For a fixed cooling target heat flux, the ratio of the heat sink thermal resistance to the respective single-stage value and the attainable COP in a cascaded cooler are determined as a function of the number of stages. Numerical simulations clearly indicate that the thermal resistance of the hot side heat sink is the controlling factor in determining the overall performance of a multi-stage thermoelectric cooler.
Keywords :
Refroidisseur , flux thermique , Analyse thermique , Performance , Thermoelectricity , Refrigerator , Cooler , thermal analysis , heat flux , Thermoélectricité , Performance , Réfrigérateur
Journal title :
International Journal of Refrigeration
Serial Year :
2011
Journal title :
International Journal of Refrigeration
Record number :
1343875
Link To Document :
بازگشت