Sedaghat، Ahmad نويسنده , , Tahmasebi، Ahmad نويسنده Islamic Azad University, Najafabad Branch, Najafabad, I.R. of Iran , , Kalbasi، Rasool نويسنده Islamic Azad University, Najafabad Branch, Najafabad, I.R. of Iran , , Moghimi Zand، Mahdi نويسنده School of Mechanical Engineering, College of Engineering, University of Tehran ,
Issue Information :
دوفصلنامه با شماره پیاپی 0 سال 2013
Pages :
16
From page :
59
To page :
74
Abstract :
In this paper, a hybrid solid oxide fuel cell (SOFC) and micro gas turbine (MGT) power system is parametrically studied to evaluate the effect of different operating conditions. The SOFC/MGT power system includes SOFC reactor, combustion chamber, compressor and turbine units, and two heat exchangers. The effects of fuel utilization, temperature, and pressure are assessed on performance of the hybrid SOFC/MGT power system using energy and exergy analyses. This study reveals that the main exergy loss occurs in the external reformer and the maximum achievable output power is about 7kW for the hybrid system. Finally, the promising first law thermal efficiency of up to 83% is achieved when the second law efficiency enhances to 65% for the hybrid system.