• Title of article

    Development of empirical correlations for non-adiabatic capillary tube based on mechanistic model

  • Author/Authors

    Sarker، نويسنده , , Debasish and Jeong، نويسنده , , Ji Hwan، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    10
  • From page
    974
  • To page
    983
  • Abstract
    Capillary tubes play a vital role in the refrigeration cycle, as they reduce the temperature of the refrigerant. The non-adiabatic capillary tube (capillary tube-suction line heat exchanger: CT-SLHX) is widely incorporated into small refrigeration systems to enhance the cooling performance and ensure that only the refrigerant vapor enters the compressor. It is necessary to develop an accurate and fast-running non-adiabatic capillary tube model, as the performance of the refrigeration cycle simulation tool is largely dependent on the accuracy and run-time its component models. In the present study, a reliable mechanistic model was used to generate reference data. An empirical model was developed based on the data produced by this mechanistic model. This new empirical model was validated against experimental measurements available in the literature for R-134a and R-600a. The new model is fast-running and its performance metrics are in good agreement with experimentally measured data.
  • Keywords
    Heat Exchanger , Refrigerating system , SIMULATION , Tube capillaire , Système frigorifique , ةchangeur de chaleur , capillary , SIMULATION
  • Journal title
    International Journal of Refrigeration
  • Serial Year
    2012
  • Journal title
    International Journal of Refrigeration
  • Record number