Title of article :
Thermodynamic optimization of an absorption heat transformer
Author/Authors :
Zebbar، نويسنده , , Djallel and Kherris، نويسنده , , Sahraoui and Zebbar، نويسنده , , Souhila and Mostefa، نويسنده , , Kouider، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
9
From page :
1393
To page :
1401
Abstract :
In this paper questions relating to the performance optimization of heat driven pump systems are discussed. For this purpose a mathematical model for LiBr/H2O absorption heat transformer (AHT) operating according to the endo-irreversible cycle is elaborated. The model is exploited to find out the optimal operating parameters using the so called structural analysis. It shows the influence of some operating parameters on the local irreversibility rates with respect to the overall AHT irreversibility rate. At the end of this work a comparison is performed of the COP, first and second law efficiencies obtained for the optimal operating regime to those calculated for real operating conditions for an already existing AHT. It is concluded that for the same thermal powers and heat transfer parameters, an increase is performed of the first and second law efficiencies equal to 10% and 5.3% consecutively at the obtained optimal operating regime.
Keywords :
Optimisation , ABSORPTION , Exergy , Heat transformer , Irreversibility , low temperature , optimization , ABSORPTION , exergie , Irreversibilité , Basse température , Transformateur de chaleur
Journal title :
International Journal of Refrigeration
Serial Year :
2012
Journal title :
International Journal of Refrigeration
Record number :
1344615
Link To Document :
بازگشت