Title of article
Characteristics of water vapor turbocompressors applied in refrigeration and heat pump systems
Author/Authors
?arevski، نويسنده , , M.N. and ?arevski، نويسنده , , V.N.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
13
From page
1484
To page
1496
Abstract
Interdependence between centrifugal stage pressure ratio, peripheral Mach number and impeller peripheral speed, as well the influence of the refrigerating capacity on the dimensions of the centrifugal compressor are determined to obtain the range of reasonable usage of R718 refrigerating/heat pump systems. The deep vacuum operating conditions, the low specific volumetric cooling capacity of the R718 and the small molecular mass of the water are the peculiarities which determined the main parameters of the centrifugal compressor and the range of rational application of the R718 refrigerating/heat pump systems. The high peripheral impeller speed, high Mach number and high pressure ratio cause separated jet-wake flow and transonic flow phenomena in the compressor flow field. Estimation of the flow characteristics and of the performance characteristics of the water vapor centrifugal compressors is presented, using results of CFD simulations and experimental investigations for high pressure ratio centrifugal compressors.
Keywords
Water vapor , Flow , Refrigeration , Heat pump , Vapeur dיeau , Compresseur centrifuge , ةcoulement , Froid , Pompe à chaleur , Centrifugal compressor
Journal title
International Journal of Refrigeration
Serial Year
2012
Journal title
International Journal of Refrigeration
Record number
1344641