Title of article
Flash gas bypass in mobile air conditioning system with R134a
Author/Authors
Tuo، نويسنده , , Hanfei and Hrnjak، نويسنده , , Pega، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
9
From page
1869
To page
1877
Abstract
This paper demonstrates that the performance of a mobile air conditioning system (with a microchannel evaporator modified to be single pass) operating normally with R134a in direct expansion mode can be significantly improved when switched to flash gas bypass (FGB) mode. When operated at the same compressor speed, the system in FGB mode produces about 13%–18% more cooling capacity at 4%–7% higher COP than DX mode. When the compressor speed was adjusted to maintain the same cooling capacity, the COP improved 37%–55%. Two main reasons are identified and discussed: 1) improved refrigerant distribution and 2) reduction of refrigerant pressure drop.
Keywords
Système Conditionnement dיair , Two-phase flow , Refrigerant distribution , Microchannel evaporator , Air-conditioning system , ةcoulement diphasique , Distribution du frigorigène , Microcanal évaporateur