Title of article :
A CFD analysis of the flow structure inside a steam ejector to identify the suitable experimental operating conditions for a solar-driven refrigeration system
Author/Authors :
Allouche، نويسنده , , Yosr and Bouden، نويسنده , , Chiheb and Varga، نويسنده , , Szabolcs، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
10
From page :
186
To page :
195
Abstract :
This paper presents a numerical study of a steam ejector using CFD with the objective of identifying suitable experimental conditions that allows for a reliable ejector cycle operation. The flow structure and the mixing process inside the ejector were assessed for a range of operating conditions typical for a solar driven air conditioning system. The effect of varying the condenser pressure was studied. It was found that for relatively low condenser pressures (<2.5 kPa), two distinct shock waves occurred in the diffuser section resulting in a reduced re-compression efficiency, although it did not have a direct impact on the entrainment ratio. The effect of generator pressure was also studied. It was found that the entrainment ratio showed a maximum for constant condenser conditions. A near optimal condition of 70 kPa generator and 3 kPa condenser pressures were identified and tested in a preliminary experiment carried out with the solar driven ejector system installed in Tunis.
Keywords :
Ejecteur de vapeur , Dynamique des fluides computationnelle , Taux dיentraînement , flow structure , Expérimentation , steam ejector , Computational fluid dynamic , Entrainment ratio , Experimentation , Structure de lיécoulement
Journal title :
International Journal of Refrigeration
Serial Year :
2014
Journal title :
International Journal of Refrigeration
Record number :
1345927
Link To Document :
بازگشت