Title of article
Measurement of thermal wall-load distribution caused by the locked mode in a reversed-field pinch plasma
Author/Authors
Yagi، نويسنده , , Y. and Sekine، نويسنده , , S. and Koguchi، نويسنده , , H. and Bolzonella، نويسنده , , T. and Sakakita، نويسنده , , H.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
4
From page
1144
To page
1147
Abstract
Spatially localized heat flux due to the locked mode in a reversed-field pinch device, TPE-RX, is investigated by using a multipoint vessel temperature monitoring system (VTMS) which has 268 thermocouples distributed on the outer surface of the vessel system. It is shown by two-dimensional mapping that the locally enhanced thermal wall load correlates closely with the mode locking positions. Heat flux shows spatial peaks (full width at half maximum) of ∼10° and ∼100° in the toroidal and poloidal directions, respectively. Typical heat flux at the locked position is estimated to be of the order of 100 MW/m2, and the increment of the vessel temperature on the plasma side-surface exceeds 1000° with 0.35 MA plasma current.
Keywords
Locked mode , thermal load , Reversed field pinch
Journal title
Journal of Nuclear Materials
Serial Year
2001
Journal title
Journal of Nuclear Materials
Record number
1348975
Link To Document