Title of article :
Evaluation of microsieve membrane design
Author/Authors :
G. Brans، نويسنده , , J. Kromkamp، نويسنده , , N. Pek، نويسنده , , D. J. Gielen، نويسنده , , J. Heck، نويسنده , , C.J.M. van Rijn، نويسنده , , R.G.M. van der Sman، نويسنده , , C.G.P.H. Schroën، نويسنده , , R.M. Boom، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
5
From page :
344
To page :
348
Abstract :
In principle, microsieve membranes have high fluxes, due to their extremely low flow resistance and their uniform pore size. However, it was found experimentally, that the design of the support structure, even though its flow resistance is negligible, had great effect on the flux and the evolution of pore blocking. This finding was quantified using computational fluid dynamics (CFD) simulations of the flow through the microsieve. From the CFD calculations, we could conclude that the design of a microsieve should necessarily encompass the design of the top layer and the support structure together. The first design of the microsieve only had 30% of the maximum possible flux. It was shown that the channel height between the pore field and the support structure should be at least 150 μm for optimal use of the microsieve.
Keywords :
Microfiltration , membrane , Membrane design , CFD , Pore-blocking
Journal title :
Journal of Membrane Science
Serial Year :
2006
Journal title :
Journal of Membrane Science
Record number :
1352380