Title of article :
On-line extraction of the variance caused by burn-up in in-core three-dimensional power distribution
Author/Authors :
Yaqi، Wang نويسنده , , Zhengpei، Luo نويسنده , , Fu، Li نويسنده , , Wenfeng، Liu نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 2001
Pages :
-304
From page :
305
To page :
0
Abstract :
In most of PWRs, the ex-core ion-chambers are the sole real-time sensors to respond to in-core power and its axial offset. However, the calibration coefficient of the ion-chambers depends on the (3D) power distribution and varies with the bum-up. People expect to know the variance in distribution caused by burn-up directly from the signals of ion-chambers. This expectation is not realized as yet, because an ion-chamber almost only responds to its nearest fuel assemblies. The authors then developed a two-step method for burn-up characteristic extraction: the harmonics synthesis method and harmonicsʹ burn-up grouping. Using the extracted burn-up characteristics, the relationship between the readings of the ex-core ion-chambers and the in-core 3D power distribution is set up. Through the simulation on the heating reactor, the method of bum-up characteristic extraction is verified under engineering conditions. It is possible to on-line extract the variance caused by burn-up in 3D power distribution.
Keywords :
Synaptic plasticity , NMDA receptor , AMPA receptor , Hippocampus , Fluctuations
Journal title :
Nuclear Engineering and Design
Serial Year :
2001
Journal title :
Nuclear Engineering and Design
Record number :
13547
Link To Document :
بازگشت