Title of article :
Deterioration of mechanical properties: A cause for fuel cell membrane failure
Author/Authors :
Yatin P. Patil، نويسنده , , William L. Jarrett، نويسنده , , Kenneth A. Mauritz، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
The mechanical properties of Nafion® membranes that were degraded after periods of open circuit voltage (OCV) conditions in a fuel cell were studied. Severe decreases in membrane modulus and ductility at 80 °C and 100% relative humidity were observed. Stress-at-break values for 45 and 72 h degraded membrane–electrode assemblies (MEAs) were 6 and 9 times lower, respectively, while strain-at-break was 24 and 28 times lower, respectively, than that of a control MEA. Contractile stresses developed in constrained hydrated membranes that were then dried were conducted as a function of drying time. A pre-OCV degraded MEA, when subjected to creep deformation at 10 MPa, showed surface cracks which were not present in the control MEA. The 72 h-degraded MEA exhibited wider cracks than those of the 45 h-degraded MEA sample. Spectroscopic analysis of degraded membranes showed various small molecule fragments associated with side chain degradation.
Keywords :
Nafion® , Mechanical failure , Fuel cell membrane , Durability , Chemical degradation
Journal title :
Journal of Membrane Science
Journal title :