Abstract :
An electrochemical sensor for measuring hydrogen concentration in liquid sodium that is based on a ternary mixture of LiCl, CaCl2 and CaHCl as the electrolyte has been developed. DSC experiments showed the eutectic temperature of this ternary system to be ∼725 K. Impedance spectroscopic analysis of the electrolyte indicated ionic conduction through a molten phase at ∼725 K. Two electrochemical hydrogen sensors were constructed using the ternary electrolyte of composition 70 mol% LiCl:16 mol% CaHCl:14 mol% CaCl2 and tested at 723 K in a mini sodium loop and at hydrogen levels of 60–250 ppb in sodium. The sensors show linear response in this concentration range and are capable of detecting a change of 10 ppb hydrogen in sodium over a background level of 60 ppb. Identification of this electrolyte system and its use in a sensor for measuring hydrogen in sodium are described in this paper.