Title of article :
Bolometric images of the three-dimensional structure of asymmetric radiative collapse in LHD
Author/Authors :
Ashikawa، نويسنده , , N. and Peterson، نويسنده , , B.J. and Sudo، نويسنده , , S. and Kostrioukov، نويسنده , , A.Yu. and Xu، نويسنده , , Y. and Shoji، نويسنده , , Coran M. H. Watanabe، نويسنده , , T. and Osakabe، نويسنده , , M. and Morita، نويسنده , , S. and Goto، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
6
From page :
1103
To page :
1108
Abstract :
The infrared (IR) imaging bolometer has the merit of being able to measure wide two-dimensional images of the plasma radiation. Two IR imaging video bolometers (IRVB, one type of IR imaging bolometer system) were installed on the large helical device (LHD). Using these IRVBs, the asymmetric radiation collapse that is similar to the multifaceted asymmetric radiation from the edge was measured in LHD. From the results of the asymmetric collapse study in LHD, the high radiation region is localized on the inboard side and under the midplane on the vacuum vessel, but this region is not the nearest point from the plasma to the first wall. From other reports on LHD, it is written that the wall recycling is not a trigger for the asymmetric radiation onset, which is confirmed by this new result.
Keywords :
Radiation collapse , MARFE , Wall recycling
Journal title :
Journal of Nuclear Materials
Serial Year :
2003
Journal title :
Journal of Nuclear Materials
Record number :
1357429
Link To Document :
بازگشت