Abstract
An experiment to remove re-deposited layers and to release hydrogen using a glow discharge in oxygen (O-GDC) has been performed in the HT-7 superconducting tokamak. In the absence of magnetic fields, the O-GDC wall conditioning had produced rapid, controlled co-deposit removal. Average removal rates, 5.2 × 1022 H-atoms/h, 5.65 × 1021 D-atoms/h and 5.53 × 1022 C-atoms/h, respectively, were obtained during 145 min O-GDC experiment in the pressure range 0.5–1.5 Pa. The corresponding removal rate of co-deposited films was ∼1.19 μm/day (26.5 g/day for carbon) based on an area of 12 m2. Compared to thermo-oxidation and O-ICR experiment, high pressure O-GDC wall conditioning promoted the oxidation and improved the C and D atoms removal. In the O-GDC experiment, the removal rates of H-atoms and D-atoms as H2O, HDO and D2O were higher than that of H2 and D2 by factors of about 20 and 50, respectively. During the 145 min O-GDC experiment, about 14.5% O-atoms were converted into carbon oxides and hydroxides, and about 5.37 × 1022 O-atoms were adsorbed on the walls corresponding to a coverage of 4.5 × 1021 O/m2 on an wall area of 12 m2. In a 100 min helium glow discharge (He-GDC) following the O-GDC experiment, 1.53 × 1022 O-atoms, about 28.5% oxygen retained on the walls, were removed. The removal rate of H-atoms in He-GDC cleaning after O-GDC experiment was lower than that in He-GDC cleaning before O-GDC experiment, which indicates that the O-GDC wall conditioning had effectively reduced hydrogen retention on the walls.
Journal title
Journal of Nuclear Materials
Serial Year
2006
Journal title
Journal of Nuclear Materials
Record number
1363651
Link To Document