Title of article :
Ni-rich precipitates in a lead bismuth eutectic loop
Author/Authors :
Kikuchi، نويسنده , , K. and Saito، نويسنده , , S. and Hamaguchi، نويسنده , , D. and Tezuka، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
5
From page :
104
To page :
108
Abstract :
Solidified LBE was sampled from the specimens, electro-magnetic pump, filter, drain valve and oxygen sensor at the JAEA Lead Bismuth Loop-1 (JLBL-1) where the structural material was made of SS316. The concentration of Ni, Fe and Cr in LBE were analyzed by the Inductive Coupled Plasma atomic emission spectrometer. It was concluded that the solution of Ni into LBE was not saturated although the concentration of Fe and Cr almost achieved to the values in the literature. A needle-type structure appeared on the surface of solidified LBE inside the tube specimens. It was found to be Ni-rich precipitates by X-ray analyses (Field Emission Scanning Electron Microscope, FE-SEM). LBE samples collected from a circulating loop after discharging did not show the amount of impurities equivalent to the LBE bulk property.
Journal title :
Journal of Nuclear Materials
Serial Year :
2010
Journal title :
Journal of Nuclear Materials
Record number :
1363951
Link To Document :
بازگشت