Title of article :
Effect of pressure on critical heat flux in uniformly heated vertical annulus under low flow conditions
Author/Authors :
Chun، Se-Young نويسنده , , Moon، Sang-Ki نويسنده , , Chung، Heung-June نويسنده , , Yang، Sun-Kyu نويسنده , , Chung، Moon-Ki نويسنده , , Schoesse، Thomas نويسنده , , ARITOMI، MASANORI نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 2001
Pages :
-158
From page :
159
To page :
0
Abstract :
Critical heat flux (CHF) experiments have been carried out in a wide range of pressure for an internally heated vertical annulus. The experimental conditions covered a range of pressure from 0.57 to 15.01 MPa, mass fluxes of 0 kg m ^(-2) s ^(-1) and from 200 to 650 kg m ^(-2) s ^(-1) and inlet subcoolings from 85 to 413 kJ kg ^(-1) Most of the CHFs were identified to the dryout of the liquid film in the annular-mist flow. For the mass fluxes of 550 and 650 kg m ^(-2) s ^(-1), the CHFs had a maximum value at a pressure of 2-3 MPa, and the pressure at the maximum CHF values had a trend moving toward the pressure at the peak value of pool boiling CUE as the mass flux decreased. The CHF data under a zero mass flux condition indicate thal both the effects of pressure and inlel subcooling on the CHF were smaller, compared with those for the CHF with a net water upflow. The Doerffer correlation using the 1995 CHF look-up table and the Bowring correlation show a good prediction capability for the present CHF data.
Keywords :
pork , bloom , refrigerated storage , Color , muscle
Journal title :
Nuclear Engineering and Design
Serial Year :
2001
Journal title :
Nuclear Engineering and Design
Record number :
13642
Link To Document :
بازگشت