Author/Authors :
Peterson، نويسنده , , B.J. and Konoshima، نويسنده , , S. and Parchamy، نويسنده , , H. and Kaneko، نويسنده , , M. and Omori، نويسنده , , T. and Seo، نويسنده , , D.C. and Ashikawa، نويسنده , , N. and Sukegawa، نويسنده , , A.، نويسنده ,
Abstract :
An imaging bolometer has been realized for the first time on a tokamak (JT-60U). The imaging bolometer utilizes a 7 cm × 9 cm × 2.5 μm gold foil and an Omega/Micron infrared (IR) camera by Indigo/FLIR (128 × 164 pixels, 70 mK, 30 fps). The imaging bolometer has an array of 12 (toroidal) × 16 (poloidal) (192 in total) channels, a noise equivalent power density of greater than 350 μW/cm2 and a frame rate of 30 fps. The field of view of the imaging bolometer is semi-tangential covering the divertor for more than 100° toroidally in addition to the entire poloidal cross-section. The data clearly shows examples of the radiation changing from strong divertor radiation to core dominated radiation in agreement with the resistive bolometer data.
Keywords :
JT60U , Divertor , radiation , Divertor diagnostic