Title of article
Performance of W/Cu FGM based plasma facing components under high heat load test
Author/Authors
Zhou، نويسنده , , Zhang-Jian and Song، نويسنده , , Shu-Xiang and Du، نويسنده , , Juan and Zhong، نويسنده , , Zhi-Hong and Ge، نويسنده , , Chang-Chun، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
6
From page
1309
To page
1314
Abstract
Three different methods, plasma spraying, infiltration-welding method and resistance sintering under ultra-high pressure, have been developed to fabricate W/Cu FGM based plasma facing components. SEM analysis showed that good grading composition of all FGM samples had been obtained. Water quenching and electron, or laser beam test facilities have been utilized to investigate and compare thermal shock behavior and performance under high heat load. It is found that the grading at the interface between W and Cu is very effective for the reduction of thermal stress. W/Cu FGM fabricated by infiltration-welding method has the best thermal shock resistance among these three kinds of W/Cu FGM.
Keywords
graded materials , Plasma facing component , Tungsten , Thermal shock
Journal title