Title of article
A Geometrical approach to evaluating the heat flux peaking factor on first wall components
Author/Authors
Mitteau، نويسنده , , R. and Stangeby، نويسنده , , P.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
4
From page
1022
To page
1025
Abstract
In magnetic fusion experiments, a simple technique to evaluate the heat flux on first wall components is a key to controlled plasma surface interaction. The heat flux can be characterized by the peaking factor which is the ratio of the peak heat flux to the average heat flux. The peaking factor can be calculated exactly using simple derivations and standard software tools. This analysis is applied to an Iter class experiment for plasma-wall contact during start up phases at 15 MW, in idealised, realistic and misaligned situations. Even though the peaking factors are usually above 10, the peak heat load on the wall remains moderate at a few MW/m2.
Journal title
Journal of Nuclear Materials
Serial Year
2009
Journal title
Journal of Nuclear Materials
Record number
1365485
Link To Document